BOREWELL PUMP ( MAINTENANCE )
GENARAL DESCRIPTION
Borewell pumps are designed to pump the water from
100ft to 500ft Borewell pumps are available 1, 1.5 , 2 , 2.5 , 3 , 5 & 7.5 HP
capacities also higher capacities Borewell pumps from 10HP to 40HP supplied
for specialapplications
MAINTENANCE SCHEDULE
Daily
Clean the bore well pump thoroughly
* check the oil level in the crankcase ,replenish with the correct grade if required
* check the belt tension
* Every 500 hours operration
1. check the borewell pump for satisfactory operation which include
* Operational noice and vibration.
*Tightness of mounting bolts and other fasteners .
*Air leaks at the pressure line ,center -cooler , drain value etc
2. Dismantle the suction filter and clean it .change the filter element if it is contaminated too much and then re-assemble on the bore wellpump .
3. Examine the lubricating oil in the crankcase . drain the oil if necessary and renew . note that the borewell pump should be run for a short while and draining of the oil should be done when the oil is warm